Battery Test System
Equipment Details / Features
1.0 Charge/Discharge Channels : 22 nos Bitrode make •Voltage 0 - 18 Volts with accuracy 0.1% •Current 0 - 25 amps 14 channels, 0 -50 amps 6 channels, 0 - 100 amps 2 Channels with accuracy 0.1% •Temperature 0 -200 degree with accuracy 1% •Programmable up 100 segments •Use:- to charge and discharge battery for conducting capacity, life and overcharge endurance tests. 2.0 High Rate Dischage Tester : 1 no Bitrode make •Voltage 0 - 18 Volts with accuracy 0.1% •Current 0 - 1500 amps with 0.1 % accuracy and 1 amp resolution •Cut off voltage 0 V up to 1000 amps and 2.7 V from 1000 amps to 1500 amps. •Temperature 0 -200 degree with accuracy 1% •Programmable up 100 segments •Use:- To carry out high Rate discharge Test i.e. Cranking Test 3.0 High Rate Charge/Discharge Tester : 1 no. Bitrode make •Voltage 0 - 48 Volts with accuracy 0.1% •Current 0 - 1000 amps with 0.1 % accuracy and 1 amp resolution •Cut off voltage 0 V up to 1000 amps and 2.7 V from 1000 amps to 1`500 amps. •Temperature 0 -200 degree with accuracy 1% •Programmable up 100 segments •Use:- To carry out High Rate Charge/Discharge Tests on batteries used for EV application (Dynamic Stress Test) and High Rate Discharge test 4.0 Density Meter : 1 nos Anton Par make •Range - 0 - 1.999 g/cmc •Resolution 0.0001 gm/cmc •Uncertainty :- + 0.001 gm/cmc •Temperature 0 - 40 degree •Resolution 0.1 degree •battery operated
Testing Conducted
Lead Acid Storage Batteries
Test Standard Followed
Any Other Information
This test facility can also be utilized for quality assurance & developmental work and R&D study.
Images

